Comtech EF Data CDM-700 User Manual
Page 174

CDM-700 High Speed Satellite Modem
Revision 5
Remote Control
MN/CDM700.IOM
11–24
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Serial Number
N/A
9 bytes
Query only.
Used to query the unit 9-digit serial number. Unit returns its S/N in
the form xxxxxxxxx.
Example: SNO=176500143
N/A
SNO?
SNO=xxxxxxxxx
Temperature
N/A
3 bytes
Query only.
Unit returns the value of the internal temperature, in the form of
sxxx (ºC).
Example: TMP=+026
N/A
TMP?
TMP=sxxx
Reboot
RBT=
1 byte
Command only.
Reboot.
Where n is:
1=System reboot
Example: RBT=1
RBT=
RBT?
RBT*
RBT#
N/A
RBT=n
Firmware
Revision
Details
N/A
1 bytes
Command or Query.
Firmware Revision Details
i=Bulk Image (1 or 2)
a=Firmware Image
b=Firmware Revision
c=Firmware Date
Example: FRW?1 (Firmware revision details for bulk image 1)
FRW=
FRW?
FRW*
FRW#
FRW?i
FRW={CR}Boot:{CR}a,
b,c{CR}Bulki:{CR}a,b,c{
CR}a,b,c…
E3/T3/STS1
Mode Select
ETS=
3 bytes
Command or Query.
Sets the E3/T3/STS1 interface card mode.
s=Interface Slot (1 or 2)
p=Interface Port (1 or 2)
m=Mode
0=E3
1=T3
2=STS1
(Note: Command valid Only with CDI-10 Dual G.703 interface)
Example: ETS=111 (sets Interface 1, Port 1 to T3 mode)
ETS=
ETS?
ETS#
ETS*
ETS?sp
ETS=spm