beautypg.com

Comtech EF Data CDM-700 User Manual

Page 165

background image

CDM-700 High Speed Satellite Modem

Revision 5

Remote Control

MN/CDM700.IOM

11–15

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Interface
Enable

RIE=

3 bytes

Command or Query.
Interface Channel Enable/Disable, where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Rx Interface Status, where:
0=Disabled
1=Enabled

Example: RIE = 111 (Enables receive on interface slot 1, channel 1)

RIE=
RIE?
RIE*
RIE#

RIE?sc

RIE=scx
(see description of
arguments)

Rx Clock
Source

RCK=

3 bytes

Command or Query.
Rx Clock Source (For Data Rate Accuracy), where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Rx Clock Source, where:
0=Rx Satellite
1=Tx-Terrestrial
2=External Reference Clock (CDI-10 Only)
3=Internal (CDI-50 OC-3 and CDI-60 HSSI Only)

Example: RCK=111 (selects Tx-Terrestrial)

RCK=
RCK?
RCK*
RCK#

RCK?sc

RCK=scx
(see description of
arguments)

Interface
Reference
Clock

EFI=

2 bytes

Command or Query.
s=Defines which interface slot (1 or 2)
x=EXT CLK (Data Rate Accuracy), where:
0 = 1 MHz
1 = 2 MHz
2 = 2.048 MHz
3 = 5 MHz
4 = 10 MHz
5 = 20 MHz
6 = 34.368 MHz
7 = 44.736 MHz
8 = 51.840 MHz

(Note: Command valid Only with CDI-10 Dual G.703 interface)

Example: EFI=14 (Selects 10MHz on slot 1)

EFI=
EFI?
EFI*
EFI#

EFI?s

EFI=sx
(see description of
arguments)

Eb/No Alarm
Point

EBA=

4 bytes

Command or Query.
Eb/No alarm point in dB, with a range between 0.1 and 16 dB.
Resolution=0.1 dB

Example: EBA=12.3

EBA=
EBA?
EBA*
EBA#

EBA?

EBA=xx.x
(see description of
arguments)