beautypg.com

Comtech EF Data CDM-700 User Manual

Page 173

background image

CDM-700 High Speed Satellite Modem

Revision 5

Remote Control

MN/CDM700.IOM

11–23

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Frame Error
Rate

N/A

9bytes

Query only.
s=Defines which interface slot ( 1 or 2 )

Units returns the value of the calculated estimated Frame Error
Rate(LINK ERRORS/RX PACKETS RECEIVED) in the form a.b
x 10

-c

. First three bytes are the value. Last two bytes are the

exponent. Returns 0.0E+00 0r 1.0E+00 if the Gigabit Traffic is
RX PACKETS Received 0..

Example: FER=17.8E-03 (which is Slot One FER= 7.8 x 10

-3

)

Valid for Gigbait Interface Only.
Value is reset to 0.00E+00 if GBEI Statistics Cleared.

N/A

FER?s

FER=sa.bExcc

Rx BER
Alarm
Threshold

BTH

1bytes

Command or Query.
Sets and Returns BerThreshold
a=Ber Threshold
0= NONE
3= 1E10-3
4 =1E10-4
5= 1E10-5
6= 1E10-6
7= 1E10-7
8 =1E10-8

Example BTH=3(Sets Ber Alarm Threshold to 1E10-3)

BTH=
BTH?
BTH#

BTH?

BTH =

1E10-3

Returns string of BER Alarm
Threshold

Local/Remote
Status

LRS=

1 byte

Command or Query.
Local/Remote status, where:
0=Local
1=Serial
2=Reserved
3=Ethernet

Example: LRS=1 (which is Serial Remote)

LRS=
LRS?
LRS*
LRS#

LRS?

LRS=x

Software
Revision

N/A

34 bytes

Query only.
Unit returns the value of the internal software revision installed in
the unit, in the form of x.x.x

Example: SWR=Boot:1.0.1 Bulk1:1.0.1 Bulk2:1.0.1

N/A

SWR?

SWR=Boot:x.x.x
Bulk1:x.x.x Bulk2:x.x.x