beautypg.com

Comtech EF Data CDM-700 User Manual

Page 161

background image

CDM-700 High Speed Satellite Modem

Revision 5

Remote Control

MN/CDM700.IOM

11–11

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx Clock
Invert

TCI=

2 bytes

Command or Query.
Invert Transmit Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Transmit Clock, where:
0=Normal
1=Inverted
(Note: Command valid Only with CDI-60 HSSI interface)

Example: TCI = 11 (selects Inverted TX Clock, Slot 1)

TCI =
TCI?
TCI *
TCI #

TCI?s

TCI =sx
(see description of
arguments)

Tx Line Code

TLC=

3 bytes

Command or Query. (G.703 Parameters)
Tx Line Code, where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Defines Tx Line Code, where:
0=None ( Valid for E3, T3, and STS-1 )
1=HDB3 (Valid for E3 )
2=B3ZS ( Valid for T3 and STS-1)

(Note: Command valid Only with CDI-10 Dual G.703 interface)

Example: TLC=111 (sets Line Code to HDB3 for interface 1
channel 1)

TLC=
TLC?
TLC*
TLC#

TLC?sc

TLC=scx
(see description of
arguments)

Tx Carrier
State

TXO=

1 byte

Command or Query.
Tx Carrier State, where:
0=OFF due to front panel or remote control command
1=ON
2=RTI (receive/transmit inhibit)
3=OFF due to ext H/W Tx Carrier Off command (not a valid
argument when used as a command)

Example: TXO=1 (Tx Carrier ON)

TXO=
TXO?
TXO*
TXO#

TXO? TXO=x

(see description of