CDM-700 High Speed Satellite Modem
Revision 5
Remote Control
MN/CDM700.IOM
11–22
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Signal
Level
N/A
3 bytes
Query only.
Unit returns the value of the Rx signal level, in dBm, between +3.0
and –99.0 dBm, where;
xxx is the Rx signal level.
Examples:
RSL=+03
RSL=-41
N/A
RSL?
RSL=xxx
Rx Frequency
Offset
N/A
5 bytes
Query only.
Unit returns the value of the measured frequency offset of the
carrier being demodulated. Values range from
± 0 to ± 30 kHz, 100
Hz resolution.
Returns 99999 if the demodulator is unlocked.
Example: RFO=+02.3 (which is + 2.3 kHz)
N/A
RFO?
RFO=sxx.x
Buffer Fill
State
N/A
3 bytes
Query only.
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
xx = value of the buffer fill state, between 1 to 99%. Returns 00 if
demodulator is unlocked.
Note: Command not valid for GbEI.
Example: BFS=1133 (which is 33%, on interface slot 1 channel 1)
N/A
BFS?sc
BFS=scxx
Rx BER
N/A
8 bytes
Query only.
Units returns the value of the estimated corrected BER in the form
a.b x 10
-c
. First three bytes are the value. Last two bytes are the
exponent. Returns 0.0E+00 if the demodulator is unlocked.
Example: BER=4.8E-03 (which is BER = 4.8 x 10
-3
)
N/A
BER?
BER=a.bEscc