11–30

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Faults and
Status

N/A

8 bytes

Query only.
Unit returns the current fault and status codes for the Unit (hardware), Modulator, Demodulator, and
Interfaces, where:

a = Unit Faults:
0 = No Faults C = FPGA Load (FEC 2)
1 = Framer FPGA Not Loaded D = FPGA Load (Interface 1)
2 = 1.5 Volt Supply E = FPGA Load (Interface 2)
3 = 1.5 Volt Supply (Intfc 1) F = 192MHz PLL Fault
4 = 1.5 Volt Supply (Intfc 2) G = Ext Reference PLL Fault
5 = 3.3 Volt Supply H = Framer FPGA Temperature
6 = 5.0 Volt Supply I = Framer Temperature
7 = 12.0 Volt Supply J = Cooling Fans
8 = -12.0 Volt Supply K = Interface 1
9 = 18.0 Volt Supply L = Interface 2
A = Flash Load M = 1:1 Redundancy Switch
B = FPGA Load (FEC 1)

bb = Tx Faults:
00 = No Faults 0J = PECL Slot 1 FIFO
01 = Modulator 1.5 Volt Supply 0K = PECL Slot 2 FIFO
02 = Modulator FPGA Not Loaded 0L = Reserved
03 = Symbol Rate PLL 0M = Rserved
04 = Synthesizer Lock 0N = Reserved
05 = Digital Clock Mgmt Lock 0O = Reserved
06 = I & Q Activity 0P = Reserved
07 = Modulator Temperature 0Q = Reserved
08 = Modulator Filters 0R = Reserved
09 = Cable Slot 1 Port 1 0S = Reserved
0A = Cable Slot 1 Port 2 0T = Reserved
0B = Cable Slot 2 Port 1 0U = Reserved.
0C = Cable Slot 2 Port 2 0V = Serdes Slot 1 to Framer
0D = AIS Slot 1 Port 1 0W = Serdes Slot 2 to Framer
0E = AIS Slot 1 Port 2 0X = Serdes Modulator to FEC 1
0F = AIS Slot 2 Port 1 0Y = Serdes Modulator to FEC 2
0G = AIS Slot 2 Port 2 0Z = Serdes FEC 1 to Framer
0H = ASI Slot 1 Clock 10 = Serdes FEC 2 to Framer
0I = ASI Slot 2 Clock 11 = Serdes Framer to Modulator
13= GBEI CABLE SLOT 1
14 = GBEI CABLE SLOT 22

N/A

FLT?

FLT=aabbccde (see
description for details of
arguments

d=0
NO Change in fault status
since last poll.
D=1
Change in fault status
since last poll.
E=0
NO Change in
configuration since last
poll.
E=1
Change in configuration
since last poll.

(see description of
arguments)