Remote Control
MN/CDM700.IOM
11–10
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx Interface
Enable
TIE=
3 bytes
Command or Query.
Interface Channel Enable/Disable, where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Tx Interface Status, where:
0=Disabled
1=Enabled
Example: TIE = 111 (Enables transmit on interface slot 1, channel 1)
TIE=
TIE?
TIE*
TIE#
TIE?sc TIE=scx
(see description of
arguments)
Tx Clock
Source
TCK=
3 bytes
Command or Query.
Tx Clock Source, where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Tx Clock Source, where:
0=Internal
1=Tx Terrestrial
2=Rx Loop-Timed
3=External Reference
Example: TCK=110 (selects Internal on interface 1 channel 1)
*HSSI card not supported.
TCK=
TCK?
TCK*
TCK#
TCK?sc TCK=scx
(see description of
arguments)
Tx Data Invert
TDI=
3 bytes
Command or Query.
Invert Transmit Data, where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Invert Transmit Data, where:
0=Normal
1=Inverted
(Note: Command valid Only with CDI-10 Dual G.703 and CDI-60
HSSI interface. For HSSI the ‘c’ parameter is always ‘1’)
Example: TDI = 111 (selects Inverted TX Data)
TDI =
TDI?
TDI *
TDI #
TDI?sc
TDI =scx
(see description of
arguments)