CDM-700 High Speed Satellite Modem

Revision 5

Front Panel Operation

MN/CDM700.IOM

6–21

If Eb/No Alarm: Æ Threshold is selected:

Eb/No Alarm Threshold:
2.0 dB (
▲ ▼ E)

Select a value here, and if the Eb/No falls below this value, a receive traffic fault will be
generated.

Edit the Eb/No alarm point by selecting the digit to be edited, using the

◄ ►

arrow keys. The

value of the digit is then changed using the

▲ ▼

arrow keys. The range of values is from 0.1 to

16.0 dB. Press

ENTER

.

If Eb/No Alarm: Æ Alarm/Fault is selected:

Eb/No Alarm:
Alarm Fault Mask (
E)


Select Alarm, Fault, or Mask using the

◄ ►

arrow keys. The available choices define the

Eb/No Alarm as an Alarm, as a Fault, or to completely Mask the alarm. This choice affects
operation in 1:1 redundancy only. Press

ENTER

.

If Eb/No Alarm: Æ Alarm/Fault Æ Mask is selected:

Rx Alarm Mask:
AGC BER All-Rx-Flts (
E)

Select AGC, BER, or All-Rx-Flts using the

◄ ►

arrow keys. Press

ENTER

.

If Rx Alarm Mask: Æ AGC is selected:

AGC Alarm:
Active Mask

(E)


This choice effects operation in 1:1 redundancy only. Select Active to activate the AGC Alarm or
Mask to mask the AGC Alarm using the

◄ ►

arrow keys. Press

ENTER

.

If Rx Alarm Mask: Æ BER is selected:

BER Alarm:
Active Mask

(E)


This choice effects operation in 1:1 redundancy only. Select Active to activate the BER Alarm or
Mask to mask the BER Alarm using the

◄ ►

arrow keys. Press

ENTER

.