MN/CDM700.IOM
6–36
If Intfc1 Rx Data: Æ Invert is selected:
Intfc1 Rx Data Invert:
Normal Inverted ( E)
This feature has been added for compatibility with certain older equipment. Select Normal or
Inverted, using the
◄ ►
arrow keys, to control data inversion. Press
ENTER
.
If Intfc1 Rx: Æ Buffer is selected:
Intfc1 Rx Buffer:
Size ReCenter (E)
Select Size or ReCenter using the
◄ ►
arrow keys. Press
ENTER
.
If Intfc1 Rx Buffer: Æ Size is selected:
Intfc1 Rx Buffer Size:
10.0 mSec (0343.680 Bits)
Edit the Rx Buffer Size by selecting the digit to be edited, using the
◄ ►
arrow keys. The value
of the digit is then changed using the
▲ ▼
arrow keys. The range of values is from 5.0 to 32.0
mSecs in 0.1 mSec increments. Press
ENTER
.
If Intfc1 Rx Buffer: Æ ReCenter is selected:
Intfc1 Buffer Fill:
(046%) ReCenter (E)
The percentage (046%) indicates the current buffer fill status. Select ReCenter, using the
◄ ►
arrow keys, to reset the buffer to the midpoint (50%). Press
ENTER
.
If Intfc1 Rx: Æ Clock is selected:
Intfc1 Rx Clock:
Source Invert (E)
Select Source or Invert using the
◄ ►
arrow keys. Press
ENTER
. The selections are as
follows: