CDM-700 High Speed Satellite Modem

Revision 5

Front Panel Operation

MN/CDM700.IOM

6–40

Intfc1 Gigabit Ethernet:

Æ Rx

Intfc1 Rx:
Data Enable (
E)

Select Data or Enable using the

◄ ►

arrow keys. Press

ENTER

.

If Intfc1 Rx: Æ Data is selected:

Intfc1 Data Rate:
Rx:075.000000 Mbps (E)

Intfc1 Data Rate:
Rx:Disabled (E)


Edit the Rx Data Rate by selecting the digit to be edited, using the

◄ ►

arrow keys. The value

of the digit is then changed using the

▲ ▼

arrow keys. The range of values is from 1.0 to 155.0

Mbps. Note that the modem Symbol Rate limits of 1.0 to 64.0 Msps makes some choices of
Modulation Type, FEC Coding and Data Rate selection invalid. Once the Rx Data Rate is edited,
Press

ENTER

.

If Rx: Disabled is displayed, the port is turned Off (0 Mbps).

If Intfc1 Rx: Æ Enable is selected:

Intfc1 Rx Enable:
Enable Disable (
E)

This selection activates or deactivates the receive (Rx) side of this interface. Disabling the Rx
side deactivates it and changes the data rate to 0.

Select Enable or Disable using the ◄ ► arrow keys. Press

ENTER

.