S-0-0103 modulo value, S‐0‐0103 – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 76

SIDNs
S00103 Modulo Value
This parameter contains the modulo value. If the modulo format is selected in bit 7 of S00076, this
parameter defines the modulo interval. If the modulo format is active, the values of the position interface are
within the interval [0…S001031].
Attributes
Name
Value
Format
udec
Data length
32
Decimal point
0
Min value
1
Max value
2147483647
Default value
1048576
Unit
inc
Changeable in EtherCAT state
PreOp
Cyclic transfer
No
Device parameter
No
Related to interface revision
For continuously moving axes, the modulo function is used to log the position within a machine cycle. The
modulo function of the AX5000 replaces complex controller programming with a simple parameterisation.
Note
IDNs involved
67], S00554, P00010, P00159,
P00270, P00277, P00279
Note
Additional functional description
AX5000 / Modulo
AX5000 IDNDescriptions
76
Version 3.1