S-0-0410 probe 1 negative latched (counter), Single mode – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 176

SIDNs
S00410 Probe 1 negative latched (Counter)
This parameter indicates whether a positive edge occurred at Probe 1.
Attributes
Name
Value
Format
binary
Data length
16
Decimal point
0
Min value
Max value
Default value
Unit
Changeable in EtherCAT state
No
Cyclic transfer
AT
Device parameter
No
Related to interface revision
No
This parameter can be assigned an IDN, so that a realtime status bit can be assigned to this parameter. The
drive only sets bit 0 of this parameter if the command S00170 is enabled, S00405 is set to 1, and the
negative edge of S00401 is enabled.
If a negative edge occurs at the input, the drive saves the parameterised source value in S00131. The drive
resets this bit, if the controller cancels the command S00170, or if S00405 is reset to 0.
Bit pattern:
Bit
Meaning
0
Probe 1
Probe 1
0 = not enabled
1 = enabled
1 – 15 Reserved
Note
IDNs involved
Note
Additional functional description
AX5000 / Probe unit
Single mode
S00409 Probe 1 negative latched / Single mode
Format
Size in bit
Offset
Properties
Enum
16
0
AX5000 IDNDescriptions
176
Version 3.1