S-0-0124 standstill window – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 102

SIDNs
S00124 Standstill window
The parameter contains a velocity threshold value, which is used to detect a motor or axis standstill.
Attributes
Name
Value
Format
udec
Data length
32
Decimal point
0
Min value
0
Max value
17895697
Default value
89478
Unit
rev/(2
30
ms)
Changeable in EtherCAT state
PreOp, SafeOp, Op
Cyclic transfer
No
Device parameter
No
Related to interface revision
If the magnitude of actual velocity falls below the value of this parameter, the axis velocity is in the socalled
standstill window. This results in bit 1 of S00013 being set. In addition, this window is evaluated in the
AxisStateMachine. Further actions are executed, depending on this threshold value. For example, in motors
with holding brake, the brake is engaged depending on this window. Default (89478) equates to 5 rpm.
Note
IDNs involved
Note
Additional functional description
See also AxisStateMachine documentation (to do!).
AX5000 IDNDescriptions
102
Version 3.1