S-x-0082 positive torque limit value, Sx0082 positive torque limit value – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 60

SIDNs
Sx0082 Positive torque limit value
The parameter limits the set torque/force value of the drive. It defines the positive upper limit. If this limit is
exceeded, the drive sets bit 3 of S00013. The base for the percentage figure is P00092.
Attributes
Name
Value
Format
udec
Data length
16
Decimal point
1
Min value
0.0
Max value
100.0
Default value
100.0
Unit
%
Changeable in EtherCAT state
PreOp, SafeOp, Op
Cyclic transfer
MDT
Device parameter
No
Related to interface revision
No
Note
Parameter set switchover is possible!
This IDN exists as S00082; S10082; S20082; S30082;
S40082; S50082; S60082, and S70082. Ex factory, all values are identical.
Note
IDNs involved
Note
Additional functional description
AX5000 / parameter set switchover
AX5000 IDNDescriptions
60
Version 3.1
- Bus Terminal System (19 pages)
- EP-xxxx-xxxx (19 pages)
- BK2000 (30 pages)
- LC3100 (67 pages)
- BK4000 (28 pages)
- BK3xx0 (95 pages)
- BK5000 (12 pages)
- LC5200 (32 pages)
- BK7000 (29 pages)
- BK7500 (32 pages)
- BK7300 (40 pages)
- BK8100 (26 pages)
- BC2000 (28 pages)
- BC3100 (51 pages)
- BC7300 (48 pages)
- BC8100 (36 pages)
- BC3150 (112 pages)
- KL1012 (2 pages)
- KL1114 (2 pages)
- KL1164 (1 page)
- KL1232-xxxx (4 pages)
- KL1501 (19 pages)
- KL1512 (15 pages)
- KL2521-0024 (18 pages)
- KL2512 (21 pages)
- KL2612 (4 pages)
- KL2622 (9 pages)
- KL3062 (24 pages)
- KL3064 (20 pages)
- KL4132 (19 pages)
- KL4034 (25 pages)
- KL3302 (23 pages)
- KL3351 (18 pages)
- KS3681 (43 pages)
- KL4112 (18 pages)
- KL5001 (16 pages)
- KL5051 (17 pages)
- KL5101-0012 (21 pages)
- KS5111-0000 (21 pages)
- KL5121 (19 pages)
- KL6021 (20 pages)
- KL6051 (17 pages)
- Z1000 (2 pages)
- KL6071 (12 pages)
- Z1003 (2 pages)