S-0-0405 probe 1 enable, S‐0‐0405 – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 173

SIDNs
S00405 Probe 1 enable
This parameter is used to activate probe unit 1 of the drive. This parameter can be linked with a realtime
control bit (S00301), so that activation is possible via the MasterControlWord (S00134).
Attributes
Name
Value
Format
binary
Data length
16
Decimal point
0
Min value
Max value
Default value
Unit
Changeable in EtherCAT state
PreOp, SafeOp, Op
Cyclic transfer
MDT
Device parameter
No
Related to interface revision
No
The drive checks this parameter as long as S00170 is enabled. To start a new measuring probe cycle, the
value of this IDN must be changed from 0 to 1.
Bit pattern:
Bit
Meaning
0
Probe 1
Probe 1
0 = not enabled
1 = enabled
1 – 15 Reserved
Note
IDNs involved
S0130, S‐0131 [
Note
Additional functional description
AX5000 / Probe Unit
Also see about this
2 S00130 Probe value 1 positive edge [
2 S00303 Allocation of realtime control bit 2 [
AX5000 IDNDescriptions
173
Version 3.1