S-0-0011 class 1 diagnostic (c1d) – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 12

SIDNs
S00011 Class 1 diagnostic (C1D)
The parameter contains error groups that trigger a "drive shut down" error.
Attributes
Name
Value
Format
Binary
Data length
16
Decimal point
0
Min value
Max value
Default value
Unit
Changeable in EtherCAT state
No
Cyclic transfer
AT
Device parameter
No
Related to interface revision
No
If an error is diagnosed in the drive, this results in an error response and the error bit is set, as described
below. In addition, error bit 13 is set by S00135 to "1" and is only reset to "0" by the drive when the drive
has executed the command S00099 and any errors have been cleared.
To precisely identify the error, read the error memory.
Bit pattern:
Bit Meaning
0
Overload shut down
Overload shut down
0 = no error
1 = error
1
Amplifier overtemperature shut down
Amplifier overtemperature shut down
0 = no error
1 = error
2
Motor overtemperature shut down
Motor overtemperature shut down
0 = no error
1 = error
3
Cooling error shut down
Cooling error shut down
0 = no error
1 = error
4
Control voltage error
Control voltage error
0 = no error
1 = error
5
Feedback error
Feedback error
0 = no error
1 = error
AX5000 IDNDescriptions
12