S-0-0033 secondary operation mode 1, S‐0‐0033 – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 37

SIDNs
S00033 Secondary operation mode 1
The parameter specifies the first secondary mode.
Attributes
Name
Value
Format
Binary
Data length
16
Decimal point
0
Min value
Max value
Default value
2
Unit
Changeable in EtherCAT state
PreOp
Cyclic transfer
No
Device parameter
No
Related to interface revision
from 204: additional operating modes “using dynamic MDT”
The operating modes (main mode or secondary modes 1 to 3) are activated via bits 9 and 8 in the
DriveControlWord of the MDT (S00134). The DriveStatusWord (S00135) of the drive telegram (AT)
indicates the activated mode via bits 9 and 8.
Bit pattern:
Value
Description
0
no mode of operation
no mode of operation
1
torque control
Torque control
2
velo control
Velocity control
3
Pos ctrl feedback 1
Position control, feedback system 1
4
Pos ctrl feedback 2
Position control, feedback system 2
11
Pos ctrl feedback 1 lag less
Position control lag less, feedback system 1
12
Pos ctrl feedback 2 lag less
Position control lag less, feedback system 2
32769
torque control using dynamic MDT
Torque control using dynamic MDT
32770
velo control using dynamic MDT
Velocity control using dynamic MDT
32771
Pos ctrl feedback 1 using dynamic MDT
Position control using dynamic MDT, feedback system 1
32772
Pos ctrl feedback 2 using dynamic MDT
Position control using dynamic MDT, feedback system 2
32779
Pos ctrl feedback 1 lag less using dynamic MDT
Position control lag less using dynamic MDT, feedback system 1
AX5000 IDNDescriptions
37