S-x-0137 negative acceleration limit value, Sx0137 negative acceleration limit value – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 112

SIDNs
Sx0137 Negative acceleration limit value
The parameter limits the maximum drive delay (negative acceleration) to the specified value. The
acceleration is negative if the magnitude of the velocity decreases.
Attributes
Name
Value
Format
udec
Data length
32
Decimal point
2
Min value
0.52
Max value
10737418.24
Default value
6283.18
Unit
rad/s
2
Changeable in EtherCAT state
PreOp
Cyclic transfer
No
Device parameter
No
Related to interface revision
This parameter influences the axis control in all position and velocitycontrolled operating modes. The
dynamics of the controlside set value specification should be lower than the limit configured here, because
otherwise the axis cannot follow the specified acceleration, resulting in discrepancies between the set and
actual positions (following error).
Note
Parameter set switchover is possible!
This IDN exists as S00137; S10137; S20137; S30137; S40137; S50137; S60137
and S70137. Ex factory, all values are identical.
Note
IDNs involved
AX5000 IDNDescriptions
112
Version 3.1