S-0-0188 idn-list of configurable data in the mdt, Actual length, Max length – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 130: All operation data, S‐0‐0188

SIDNs
S00188 IDNlist of configurable data in the MDT
The parameter contains a list of parameters whose data can be processed cyclically by the drive as set
values.
Attributes
Name
Value
Format
idn
Data length
12064
Decimal point
0
Min value
Max value
Default value
Unit
Changeable in EtherCAT state
No
Cyclic transfer
No
Device parameter
No
Related to interface revision
No
The AX5000 allows the telegram type "application telegram" in S00015 and therefore supports this list.
Note
Nested structure
Note the nesting depth and the structure information at the start of the descriptions.
Note
IDNs involved
Actual length
S00188IDNlist of configurable Data in the MDT / Actual length
Format
Size in bit
Offset
Properties
UINT
16
0
Max length
S00188IDNlist of configurable Data in the MDT / Max length
Format
Size in bit
Offset
Properties
UINT
16
16
All operation data
S00188IDNlist of configurable Data in the MDT / All operation data
Format
Size in bit
Offset
Properties
12032
32
AX5000 IDNDescriptions
130