S-0-0013 class 3 diagnostic (c3d) – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 16

SIDNs
S00013 Class 3 diagnostic (C3D)
The parameter contains information groups that trigger a drive information.
Attributes
Name
Value
Format
Binary
Data length
16
Decimal point
0
Min value
Max value
Default value
Unit
Changeable in EtherCAT state
No
Cyclic transfer
AT
Device parameter
No
Related to interface revision
No
If an information is diagnosed in the drive, the change bit is set, as described below. In addition, change bit
11 is set by S00135 to "1" and is only reset again when the cause has been rectified and the parameter
S00013 is read again.
In this parameter the bit is automatically reset, once the cause has been rectified.
Bit pattern:
Bit Meaning
0
Reserved
1
| n Feedback |< standstill window
This bit can be used to read the axis movement status.
0 = no information
1 = information
2
Reserved
3
|T| ≥ Tx
This bit can be used to read whether the currently applied force or torque is larger or smaller than the
TX S00126 "Torque threshold".
0 = no information
1 = information
4
15
Reserved
Note
IDNs involved
AX5000 IDNDescriptions
16
Version 3.1