S-0-0160 acceleration data scaling type, S‐0‐0160 – BECKHOFF AX5000 S-IDN Parameters User Manual
Page 118

SIDNs
S00160 Acceleration data scaling type
This parameter can be used to select different scaling types for the acceleration data in the drive. The drive
represents associated parameters at the selected scale.
Attributes
Name
Value
Format
binary
Data length
16
Decimal point
0
Min value
Max value
Default value
0xA
Unit
Changeable in EtherCAT state
No
Cyclic transfer
No
Device parameter
No
Related to interface revision
In the AX5000, percentage scaling is selected via S00086 "Torque/force data scaling type". S00160 is
therefore not evaluated.
Bit pattern:
Bit Meaning
0 2 Scaling method
Scaling method
0 = no scaling
1 = linear scaling
2 = rotary scaling
3 = ramp time (see S00446)
3 Scaling type
Scaling type
0 = preferred scaling
1 = parameter scaling
4 Units for linear / rotational scaling
Units for linear / rotational scaling
0 = meter / radian
1 = inch / reserved
5 Time unit
0 = seconds
1 = reserved
6 Data reference
0 = at the motor shaft
1 = at the load
7
15
Reserved
Note
IDNs involved
AX5000 IDNDescriptions