beautypg.com

3 sensor data records, Table 9-3, Sensor data records – Artesyn ATCA 7370 / ATCA 7370-S Installation and Use (January 2015) User Manual

Page 233: Fru information and sensor data records

background image

FRU Information and Sensor Data Records

ATCA-7370/ATCA-7370-S Installation and Use (6806800P54H)

233

9.3

Sensor Data Records

The sensors available on the blades are detailed in the table below.

For sensor threshold definition please use the "ipmitool" found on

http://sourceforge.net/projects/ipmitool/files/ipmitool/

with

the parameter "sensor".

Table 9-3 Sensor Data Records

Sensor
Number Sensor Name Sensor Type

Event/Reading
Type

Event
Data
Byte 1 Event Data Byte 2

Event Data Byte 3

Event Threshold/
Description

Assertion
Deassertion Rearm

0

HS Carrier

Hot Swap
0xF0

Sensor-
specific
discrete
0x6F

0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7

[7:4] = Cause
[3:0] = Previous State

FRU ID

0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7

Asrt

Auto

1

Hot Swap
RTM

Hot Swap
0xF0

Sensor-
specific
discrete
0x6F

0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7

[7:4] = Cause
[3:0] = Previous State

FRU ID

0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7

Asrt

Auto

2

-48V A Volts Voltage

0x02

Threshold
0x01

reading

threshold

unr uc lnr lc

Asrt / Deass Auto