1 get status command, Table 8-34, Ipmc modes – Artesyn ATCA 7370 / ATCA 7370-S Installation and Use (January 2015) User Manual

Page 210: Table 8-35, Get status command, Supported ipmi commands

background image

Supported IPMI Commands

ATCA-7370/ATCA-7370-S Installation and Use (6806800P54H)

210

Some of the following commands refer to IPMC modes which are defined as follows:

8.4.1

Get Status Command

The Get Status command can be used by the payload software to retrieve the status of the
IPMC.

Reset Carrier SDR repository

Table 8-56 on page 228

0x2E/0x2F

0x33

Table 8-34 IPMC Modes

Mode

Description

Standalone

In standalone mode, the carrier IPMC disconnects from IPMB-0 but keeps on
listening to the serial debug and payload interfaces and serving requests
coming from them, as well as managing the modules, AMC point-to-point
(P2P) and clock E-keying. Standalone mode is intended for debugging
purposes and/or operation in a non-ATCA environment. In standalone mode,
the carrier IPMC automatically activates and deactivates the on-carrier
payload and modules whenever it does not violate any carrier limitations.

Manual standalone

Manual standalone mode is equivalent to standalone mode with only one
exception: carrier IPMC control over the on-carrier payload is automatically
disabled in manual standalone mode.

Table 8-33 Pigeon Point Extension Commands (continued)

Command

NetFn
(Request/Response)

CMD

Table 8-35 Get Status Command

Type Byte

Data

Field

Request Data

1:3

PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00