Lx / Ls Series II

91

ENTRY

DESCRIPTION

TEMP

37.342°

The TEMP field is not a user selectable
parameter but rather a read-out of the internal
temperature in degrees Celsius. It is provided
for informational purposes only.

4.2.13 LIMIT Menu

The Limit menu displays the maximum available value for voltage, frequency and current range
of the power supply. This screen is used for information only and contains no user changeable
fields. The limit values shown cannot be changed.

ENTRY

DESCRIPTION

LIM LVOLT

Low Voltage
Range

Displays maximum available output voltage in
the low voltage range.

HVOLT

High Voltage
Range

Displays maximum available output voltage in
the high voltage range.

LIM LFREQ

Low Frequency
Limit

Displays minimum available output frequency.

HFREQ

High Frequency
Limit

Displays maximum available output frequency

CURR

C range

Displays maximum available current in low
voltage range and single phase mode. If only 2
or 3 phase mode is available, this value is the
maximum available current per phase.

PHASE (C)

Phase Setting

Displays phase angle for phase C. Valid values
are 120 for three phase or mode configuration,
0 for single phase only configuration. Any other
value indicates split (2) phase configuration.