beautypg.com

AMETEK Lx Series II User Manual

Page 183

background image

User Manual

Lx / Ls Series II

179

TAC 401 Tests

– Revision E, F

TAC401

Emergency SS Limits Volt and Freq. Rev E, F

Condition

Duration (s)

Nominal Voltage

A

Vnom 115V, Flow 393 Hz

1800

B

Vnom 115V, Fhigh 407 Hz

1800

Low Voltage

C

Vlow 108V, Fnom 400 Hz

1800

D

Vlow 108V, Flow 393 Hz

1800

E

Vlow 108V, Fhigh 407 Hz

1800

High Voltage

F

Vhigh 118V, Fnom 400 Hz

1800

G

Vhigh 118V, Flow 393 Hz

1800

H

Vhigh 118V, Fhigh 407 Hz

1800

TAC 401 Tests

– Revision B, D

TAC401

Emergency SS Limits Volt and Freq. Rev B, D

Condition

Duration (s)

Nominal Voltage

A

Vnom 115V, Flow 360 Hz

1800

B

Vnom 115V, Fhigh 440 Hz

1800

Low Voltage

C

Vlow 102V, Fnom 400 Hz

1800

D

Vlow 102V, Flow 360 Hz

1800

E

Vlow 102V, Fhigh 440 Hz

1800

High Voltage

F

Vhigh 124V, Fnom 400 Hz

1800

G

Vhigh 124V, Flow 360 Hz

1800

H

Vhigh 124V, Fhigh 440 Hz

1800

TAC 401 Tests

– Revision A, C

TAC401

Emergency SS Limits Volt and Freq. Rev A, C

Condition

Duration (s)

Nominal Voltage

A

Vnom 115V, Flow 360 Hz

1800

B

Vnom 115V, Fhigh 440 Hz

1800

Low Voltage

C

Vlow 104V, Fnom 400 Hz

1800

D

Vlow 104V, Flow 360 Hz

1800

E

Vlow 104V, Fhigh 440 Hz

1800

High Voltage

F

Vhigh 122V, Fnom 400 Hz

1800

G

Vhigh 122V, Flow 360 Hz

1800

H

Vhigh 122V, Fhigh 440 Hz

1800

This manual is related to the following products: