AMETEK Lx Series II User Manual
Page 198

User Manual
Lx / Ls Series II
194
TVF302
Abnormal Voltage Transients. Rev F
Condition
Duration (s)
M
45Vrms, 50 msec, tf < 0.5 cyc, tr = 11 ms
then 55Vrms, ramp up, tr = 17 msec
then 65Vrms, ramp up, tr = 31 msec
then 75Vrms, ramp up, tr = 71 msec
then 85Vrms, ramp up, tr = 87 msec
then 90Vrms, ramp up, tr = 253 msec
then 95Vrms, ramp up, tr = 6.41 sec
then 100Vrms, ramp up, tr > 10 sec
then 115Vrms.
135
N
45Vrms, 3 x 20 msec, 0.5 sec apart, tf < 0.5 cyc, tr < 0.5 cyc
58
Combined Transient
O
45Vrms, 20 msec, tf < 1.25 ms, tr < 1.25 ms
135
180Vrms, 50 msec, tf < 0.5 cyc, tr = 11 ms
then 170Vrms, ramp down, tr = 17 msec
then 160Vrms, ramp down, tr = 31 msec
then 150Vrms, ramp down, tr = 71 msec
then 140Vrms, ramp down, tr = 87 sec
then 135Vrms, ramp down, tr > 253 sec.
then 130Vrms, ramp down, tr = 6.41 sec
then 125Vrms, ramp down, tr > 10 sec
then 115Vrms.
TVF 303 Tests
– Revision F
TVF303
Abnormal Frequency Transients. Rev F
Condition
Duration (s)
Over Frequency
A
360 Hz 800 Hz, ts = 0.88 sec, dur = 0.5 cyc, tf = 0.88 sec
60
B
360 Hz 800 Hz, ts = 0.88 sec, dur = 1 sec, tf = 0.88 sec
65
C
360 Hz 800 Hz, ts = 0.48 sec, dur = 0.5 cyc, tf = 0.48 sec
56
D
360 Hz 800 Hz, ts = 0.48 sec, dur = 1 sec, tf = 0.48 sec
62
Under Frequency
E
800 Hz 360 Hz, ts = 0.88 sec, dur = 0.5 cyc, tf = 0.88 sec
61
F
800 Hz 360 Hz, ts = 0.88 sec, dur = 1 sec, tf = 0.88 sec
68
G
800 Hz 600 Hz, ts = 0.40 sec, dur = 0.5 cyc, tf = 0.40 sec
56
H
800 Hz 600 Hz, ts = 0.40 sec, dur = 1 sec, tf = 0.40 sec
60
Combined
I
600 Hz 360 Hz, ts = 0.48 sec, dur = 0.5 cyc, tf = 0.48 sec
60
600 Hz 800 Hz, ts = 0.40 sec, dur = 0.5 cyc, tf = 0.40 sec