8.5 Normal State tests

Scroll to the NORMAL STATE entry using the up and down cursor keys. Press the ENTER key to
select the NORMAL STATE screens. The screen will appear as shown in Figure 8-3.

Figure 8-3: Normal state screens

The DO160 NORMAL screens have the following tests:

1

VOLT FREQ MIN

2

VOLT FREQ MAX

3

VOLT UNBALANCE

4

WAVEFORM DISTORTION

5

VOLT MODULATION

6

FREQ MODULATION

7

POWER INTERRUPT

8

VOLTAGE SURGE

9

FREQ TRANSIENT (group 1/A(CF))

FREQ VARIATION (group 2 & 3/A(NF) & A(WF))

The above tests can be selected by scrolling to the highlighted selection using the up and down
key and the ENTER key to start the selected test. For some of these tests, numeric data entry
may be required to define the test number or the modulation rate.