AMETEK Lx Series II User Manual
Page 42

User Manual
Lx / Ls Series II
38
2.7.2 EHV Option Ls Series -Supplemental Specifications
Specifications for Ls units with -EHV voltage range option installed are same the Lx with
–EHV
option. See paragraph 2.6.2.
2.7.3 -HF Option Supplemental Specifications
Specification for Ls units with -HF frequency range option installed are same as standard Ls unit
except where noted below.
Frequency Range
Model
3000Ls-HF, 4500Ls-HF
, 6000Ls-HF
9000Ls/2-HF, 13500Ls/3-HF
12000Ls/3-HF, 18000Ls/3-HF
Three phase mode
45 Hz - 5000 Hz
45 Hz
– 2000
1
Hz
Single phase mode
45 Hz - 5000 Hz
45 Hz - 2000
1
Hz
Output
Programming
Accuracy:
< 1000 Hz
± (0.05% + 0.25 V) from 5V to FS.
> 1000 Hz
± (0.1% + 0.1% / KHz + 0.3V) from 5V to FS
Output Noise:
(20 kHz to 1 MHz)
< 250 mV
RMS typical
For output frequencies up to 1000 Hz, refer to standard measurement specifications. For output
frequencies above 1000 Hz, see table below.
Parameter
Range
Accuracy ( )
Resolution
1 Phase Mode
3 Phase Mode
Frequency
2
45.00 - 5000.0 Hz
0.1% ± 1 digit
0.01 Hz to 81.91 Hz
0.1 Hz to 819.1 Hz
1 Hz > 819.1 Hz
Phase
45.00 - 100.0 Hz
100.0 - 2000 Hz
> 2000 Hz
0.5°
2°
5°
0. 1°
RMS Voltage
0 - 400 Volts
< 1000 Hz
> 1000 Hz
0.05% + 0.25V
0.1% + 0.1% / KHz + 0.3V
0.01 Volt
RMS Current
0 - 50 Amps
0.5% + 0.15A
0.5% + 0.05A
0.001 Amp
Peak Current
0 - 150 Amps
0.5% + 0. 5A
0.5% + 0.15A
0.001 Amp
Crest Factor
1.00
– 10.00
1.5 %
1.5 %
0.01
VA Power
0 - 6 KVA
0.5% + 9 VA
0.5% + 3 VA
1 VA
Real Power
0 - 6 KW
0.5% + 9 W
0.5% + 3 W
1 W
Power Factor
0.00 - 1.00
0.03
0.01
0.01
1
Multi box systems
–HF frequency limit is set to 5000 Hz but performance to specification is guaranteed only to 2000 Hz. Above
2000 Hz, full power may not be available due to amplifier unbalance. Current measurements accuracy is affected by system
interface cable cross talk above 2000 Hz.
2
Frequency measurement specifications valid with output voltage of 30Vrms or higher. If output relay is open,
frequency measurement will return 0.0 Hz.