beautypg.com

AMETEK Lx Series II User Manual

Page 173

background image

User Manual

Lx / Ls Series II

169

TAC 105 Tests

– Revision E, F

TAC105

Frequency Modulation Rev E, F

Condition

Duration (s)

A

Fmod F = 1 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

B

Fmod F = 5 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

C

Fmod F = 10 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

D

Fmod F = 25 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

E

Fmod F = 100 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

TAC 105 Tests

– Revision B, C, D

TAC105

Frequency Modulation Rev B, C, D

Condition

Duration (s)

A

Fmod F = 1 Hz/sec, Fmod Amp = ±5 Hz

1800

B

Fmod F = 5 Hz/sec, Fmod Amp = ±1.75 Hz

1800

C

Fmod F = 10 Hz/sec, Fmod Amp = ±1.20 Hz

1800

D

Fmod F = 25 Hz/sec, Fmod Amp = ±0.85 Hz

1800

E

Fmod F = 100 Hz/sec, Fmod Amp = ±0.58 Hz

1800

TAC 105 Tests

– Revision A

TAC105

Frequency Modulation Rev A

Condition

Duration (s)

A

Fmod F = 1 Hz/sec, Fmod Amp = ±4 Hz

1800

B

Fmod F = 5 Hz/sec, Fmod Amp = ±4 Hz

1800

C

Fmod F = 10 Hz/sec, Fmod Amp = ±4 Hz

1800

D

Fmod F = 25 Hz/sec, Fmod Amp = ±4 Hz

1800

This manual is related to the following products: