beautypg.com

AMETEK Lx Series II User Manual

Page 132

background image

User Manual

Lx / Ls Series II

128

VOLT UNBALANCE

Standard/Group

RTCA

A(CF)

A(NF)

A(WF)

Voltage offset

6

6

6

8

Frequency

400

390/410

360/650

360/800

Standard/Group

Group1

Group2

Group3

Voltage offset

6

6

9

Frequency

400

360/650

360/800

Table 8-3: Normal Voltage Unbalance

This test will change the output voltage for phase A and B to 122V and phase C to a voltage
lower by a value specified by an offset. Refer to Table 8-3 for the offset value and the
Frequency. The test will repeat with the same frequency and phase A and B volt is set to 100V
and phase C set to a higher voltage specified by the offset value. The test will last 30 minutes.
The test will be repeated for a second Frequency if applicable. The test can be terminated at any
time.
The

key will terminate the test at any time.

WAVEFORM DISTORTION

This test will generate a 5% THD voltage distortion on the output voltage waveform at the
nominal voltage set. (115 V or 230 V) A clipped sine wave generates the required distortion.
The test will last for 30 minutes. The

key (backspace) will terminate the test at any time.

VOLTAGE MODULATION

This test requires a numeric value entry equal to the modulation rate in Hz. This entry value
must be between 1 Hz and 200 Hz. The amplitude modulation is calculated based on the
modulation rate as defined in Figure 8-4. This test will last for 2 minutes.

Note that the Airbus voltage modulation test levels are specified in peak to peak voltage instead
of Vrms. Table 4-4 shows the levels for the Airbus mode versus the DO160 and EUROCAE
modes as implemented in Lx/Ls firmware revision 0.98. The actual requirement for Airbus
ABD0100.8 is now specified in Vpeak peak instead of Vrms so the Airbus mode should not be
used. Use the DO160 or EURO/CAE mode instead.

Modulation

Frequency (Hz)

DO160 / EUROCAE

Modulation

Frequency (Hz)

AIRBUS

Volt RMS

Volt RMS

1

0.18

1

0.5

1.7

0.18

1.7

0.5

10

1.24

10

3.5

25

1.24

25

3.5

70

0.18

70

0.5

100

0.18

100

0.5

200

0.18

N/A

N/A

Table 8-4: Airbus mode voltage modulation.

Note: Voltage modulation levels change linearly from frequency 1.7Hz to 10Hz and again

from 25Hz to 75Hz. See Figure 8-4.