7 test steps and execution times summary – AMETEK Lx Series II User Manual
Page 159

User Manual
Lx / Ls Series II
155
11.7 Test Steps and Execution Times Summary
With the release of revision F and the accompanying test protocol handbook, the MIL-STD 704
has grown in scope considerably. Rather than duplicating all this information in this user manual,
the user is referred to the MIL-STD 704 Specification documentation for test details on each
specific test.
A summary of tests arranged by group is provided in this section. Approximate test times are
shown for each tests. Where tests differ by standard revisions, separate tables are shown for
revisions that differ in test levels and or execution times.
11.7.1 SAC Group - Singe phase 400 Hz AC tests
SAC 102 Tests - Revisions C, D, E, F
SAC102
Steady State Voltage and Frequency - Rev C-F
Condition
Duration (s)
Nominal Voltage
A
Vnom=115V, Fnom=400 Hz - Nominal
1800
B
Vnom=115V, Flow=393 Hz - Nominal
1800
C
Vnom=115V, Fhigh=407 Hz - Nominal
1800
Low Voltage
D
Vlow =108V, Fnom=400 Hz - Low
1800
E
Vlow=108V, Flow= 393 Hz- Low
1800
F
Vlow=108V, Fhigh=407 Hz - Low
1800
High Voltage
G
Vhigh=118V, Fnom=400 Hz - High
1800
H
Vhigh=118V, Flow=393 Hz- High
1800
I
Vhigh=118V, Fhigh=407 Hz - High
1800
SAC 102 Tests - Revision B
SAC102
Steady State Voltage and Frequency - Rev B
Condition
Duration (s)
Nominal Voltage
A
Vnom=115V, Fnom=400 Hz - Nominal
1800
B
Vnom=115V, Flow=395 Hz - Nominal
1800
C
Vnom=115V, Fhigh=405 Hz - Nominal
1800
Low Voltage
D
Vlow =108V, Fnom=400 Hz - Low
1800
E
Vlow=108V, Flow= 395 Hz- Low
1800
F
Vlow=108V, Fhigh=405 Hz - Low
1800
High Voltage
G
Vhigh=118V, Fnom=400 Hz - High
1800
H
Vhigh=118V, Flow=395 Hz- High
1800
I
Vhigh=118V, Fhigh=405 Hz - High
1800
SAC 102 Tests - Revision A
SAC102
Steady State Voltage and Frequency - Rev A
Condition
Duration (s)
Nominal Voltage
A
Vnom=115V, Fnom=400 Hz - Nominal
1800
B
Vnom=115V, Flow=380 Hz - Nominal
1800
C
Vnom=115V, Fhigh=420 Hz - Nominal
1800
Low Voltage
D
Vlow =108V, Fnom=400 Hz - Low
1800
E
Vlow=108V, Flow= 380 Hz- Low
1800
F
Vlow=108V, Fhigh=420 Hz - Low
1800