4.8 Setting the Power-on Initialization Values

The power source is shipped with default factory settings when the unit is powered up. The
factory settings are:

Parameter

Factory default setting

Voltage

0.0 Volt

Frequency

60 Hz

Waveform

SINE

Current limit

Maximum available current.

Current Protection Mode

Constant Current mode

Output state

OFF

Phase Rotation

A = 0°, B = 240°, C = 120°

Local / Remote State

Local. Front panel unlocked.

Table 4-3: Factory Default Power on Settings

It is possible to change the power on initialization values in one of two ways:

1. Using the IEEE-488, RS232C, LAN or USB bus interface.

2. Using the front panel.

To change the power on initialization values from the front panel, proceed as follows:

1. Set the AC power source output parameters from the front panel as you want to power

up the unit.

2. Save this setting to setup register 0 from the REGISTERS menu.

3. Select the CONFIGURATION menu and move to the POWER ON field.

4. Change the POWER ON field to REG0.

5. This will recall the settings contained in register 0 at power up.