AMETEK Lx Series II User Manual
Page 157

User Manual
Lx / Ls Series II
153
11.6.1 Revision and Group Selection
Revision and Group selection must be selected prior to running the test. Use the up and down
key to access the screen as shown in Figure 11-4
Figure 11-4: Revision/Group Menu
The default Revision is E. Revisions supported are A, B, C, D, E and F. Scroll to the REVISION
entry using the up and down cursor key. Use the shuttle to change the selection.
The default GROUP is TAC. Groups supported are SAC, TAC, SVF, TVF and SXF. Use the
shuttle to change the group selection.
11.6.2 Operating Area and Test Selection
Operating area and test define the test to perform. Use the up and down key to access the
screen as shown in Figure 11-5
Figure 11-5: Test selection Menu
Scroll to the OPArea (Operating Area) and or TEST entry using the up and down cursor keys.
Use the shuttle to change the selection. The OPArea and Test selection offer the choices shown
in Table 11-2.
OPArea
NORMAL
TRANSFER
ABNORMAL
EMERGENCY
PFAILURE
TEST:
LIMITS
POW INT
LIMITS
LIMITS
THREE
PH DIFF
VTRANS
COMB
VOLT MOD
FTRANS
PREVERSAL
FREQ MOD
DIST TH
VTRANS
FTRANS
Table 11-2: Test Selections