beautypg.com

AMETEK Lx Series II User Manual

Page 186

background image

User Manual

Lx / Ls Series II

182

SVF 103 Tests

Voltage Phase Difference tests do not apply for single-

phase EUT‟s.

SVF 104 Tests - Revision F

SVF104

Voltage Modulation Rev F

Condition

Duration (s)

Run at 400, Repeat at 360, 600 and 800 Hz

A

Vmod F = 1.0 Hz, V = 0.375 Vrms

1800

B

Vmod F = 1.7 Hz, V = 0.375 Vrms

1800

C

Vmod F = 10 Hz, V = 2.5 Vrms

1800

D

Vmod F = 25 Hz, V = 2.5 Vrms

1800

E

Vmod F = 70 Hz, V = 0.375 Vrms

1800

F

Vmod F = 100 Hz, V = 0.375 Vrms

1800

G

Vmod F = 200 Hz, V = 0.375 Vrms

1800

SVF 105 Tests

– Revision F

SVF105

Frequency Modulation Rev F

Condition

Duration (s)

Run at 400, Repeat at 362, 600 and 798 Hz

A

Fmod F = 1 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

B

Fmod F = 5 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

C

Fmod F = 10 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

D

Fmod F = 25 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

E

Fmod F = 100 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

This manual is related to the following products: