AMETEK Lx Series II User Manual
Page 191

User Manual
Lx / Ls Series II
187
SVF 401 Tests
– Revision F
SVF401
Emergency SS Limits Volt and Freq. Rev F
Condition
Duration (s)
Balanced Nominal Voltage
A
Vnom, 360 Hz
1800
B
Vnom, 400 Hz
1800
C
Vnom, 600 Hz
1800
D
Vlow, 800 Hz
1800
Balanced Low Voltage
E
108V, 360 Hz
1800
F
108V, 400 Hz
1800
G
108V, 440 Hz
300
H
108V, 480 Hz
300
I
108V, 520 Hz
300
J
108V, 560 Hz
300
K
108V, 600 Hz
1800
L
108V, 520 Hz
300
M
108V, 540 Hz
300
N
108V, 560 Hz
300
O
108V, 570 Hz
300
P
108V, 580 Hz
300
Q
108V, 600 Hz
1800
R
108V, 640 Hz
300
S
108V, 680 Hz
300
T
108V, 720 Hz
300
U
108V, 760 Hz
300
V
108V, 800 Hz
1800
Balanced High Voltage
W
118V, 360 Hz
1800
X
118V, 400 Hz
1800
Y
118V, 440 Hz
300
Z
118V, 480 Hz
300
AA
118V, 520 Hz
300
BB
118V, 560 Hz
300
CC
118V, 600 Hz
1800
DD
118V, 520 Hz
300
EE
118V, 540 Hz
300
FF
118V, 560 Hz
300
GG
118V, 570 Hz
300
HH
118V, 580 Hz
300
II
118V, 600 Hz
1800
JJ
118V, 640 Hz
300
KK
118V, 680 Hz
300
LL
118V, 720 Hz
300
MM
118V, 760 Hz
300
NN
118V, 800 Hz
1800
Unbalanced Nominal Voltage
N/A
SVF 501 Tests
Starting operations are not applicable to AC Utilization Equipment.