SXF 106 Tests

Voltage distortion spectrum test require the use of additional external equipment. In particular, a
high bandwidth (100Khz) AC source, a high frequency coupling transformer and coupling
network as shown in figure SXF106-1 of the Mil-Std 704 standard. For this test, the Lx/Ls Series
AC source can be programmed to a steady state condition of 400 Hz and Vnominal of 115 Vrms
or 230 Vrms.

Figure 11-12: Required SXF-106 Test Setup.

SXF 107 Tests

– Revision F

SXF107

Total Voltage Distortion Rev F

Condition

Duration (s)

A

0.05 % VTHD

1800

F = 100%

H3 = 2.75%

H5 = 2.75%

H7 = 1.97%

H9 = 1.53%

H11 = 1.25%

H13 = 1.06%

H15 = 0.92%

SXF 108 Tests

SXF108 are DC offset tests and are not supported by the Lx/Ls Series AC Power sources.
Contact AMETEK Programmable Power for DC Supply information.
(

[email protected]

)