beautypg.com

AMETEK Lx Series II User Manual

Page 169

background image

User Manual

Lx / Ls Series II

165

SAC 303 Tests

– Revisions B, C, D, E, F

SAC303

Abnormal Frequency Transients. Rev B, C, D, E, F

Condition

Duration (s)

Over Frequency

A

480 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec

55

B

480 Hz, 4.78 sec, tr = 160 msec, tf = 160 msec

76

Under Frequency

C

320 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec

55

D

320 Hz, 4.78 sec, tr = 160 msec, tf = 160 msec

76

Combined

E

320 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec

56

480 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec

SAC 303 Tests

– Revision A

SAC303

Abnormal Frequency Transients. Rev A

Condition

Duration (s)

Over Frequency

A

480 Hz, 0.5 cycle, tr = 333 msec, tf = 60 msec

55

B

480 Hz, 6.69 sec, tr = 333 msec, tf = 60 msec

76

Under Frequency

C

320 Hz, 0.5 cycle, tr = 333 msec, tf = 60 msec

55

D

320 Hz, 6.69 sec, tr = 333 msec, tf = 60 msec

76

Combined

E

320 Hz, 0.5 cycle, tr = 333 msec, tf = 333 msec

56

480 Hz, 0.5 cycle, tr = 333 msec, tf = 333 msec