AMETEK Lx Series II User Manual
Page 169

User Manual
Lx / Ls Series II
165
SAC 303 Tests
– Revisions B, C, D, E, F
SAC303
Abnormal Frequency Transients. Rev B, C, D, E, F
Condition
Duration (s)
Over Frequency
A
480 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec
55
B
480 Hz, 4.78 sec, tr = 160 msec, tf = 160 msec
76
Under Frequency
C
320 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec
55
D
320 Hz, 4.78 sec, tr = 160 msec, tf = 160 msec
76
Combined
E
320 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec
56
480 Hz, 0.5 cycle, tr = 160 msec, tf = 160 msec
SAC 303 Tests
– Revision A
SAC303
Abnormal Frequency Transients. Rev A
Condition
Duration (s)
Over Frequency
A
480 Hz, 0.5 cycle, tr = 333 msec, tf = 60 msec
55
B
480 Hz, 6.69 sec, tr = 333 msec, tf = 60 msec
76
Under Frequency
C
320 Hz, 0.5 cycle, tr = 333 msec, tf = 60 msec
55
D
320 Hz, 6.69 sec, tr = 333 msec, tf = 60 msec
76
Combined
E
320 Hz, 0.5 cycle, tr = 333 msec, tf = 333 msec
56
480 Hz, 0.5 cycle, tr = 333 msec, tf = 333 msec