101

Figure 4-12: Sample Transient Output Sequence

This output can be accomplished using the following transient list.

Step #

(data point)

Volt

VSlew

Frequency

FSlew

Dwell

0

70.00

MAX

360.0

MAX

0.100

1

110.00

100.0

440.0

MAX

0.900

2

130.00

MAX

240.0

800.00

0.250

3

90.00

53.3

240.0

MAX

0.750

4

90.00

MAX

460.0

MAX

1.000

5

110.00

MAX

400.0

MAX

0.800

6

88.00

MAX

400.0

MAX

0.200

7

110.00

MAX

400.0

MAX

1.000

Table 4-2: Sample Transient List