6 available options – lx series – AMETEK Lx Series II User Manual
Page 32

User Manual
Lx / Ls Series II
28
2.6 Available Options
– Lx Series
Output Options
-AX
Auxiliary outputs, 5 VAC and 26 VAC, 400 Hz. (Output D and E)
- HV
135 / 270 V range output
- EHV
200 / 400 V range output
-HF
High frequency option. Increases output frequency to 5000 Hz (single
chassis configurations) or 2000 Hz (multi-chassis models).
-LF
Low frequency option. Limits maximum output frequency to 500 Hz.
Firmware Options
- 160
RTCA/DO-160D test firmware.
Includes RCTA-DO160D, section 16, Change #2 and EURO/CAE-14D
AC tests only.
- 704
Mil Std 704 test firmware
– MIL704
Includes AC tests for Revisions D and E
- 704F
Mil Std 704 test firmware
– MS704
Includes AC tests for Revisions A through F
-ABD
Airbus ABD0100.1.8 Tests.
– ABD
Includes tables A, B and C.
This option can only be used with the provided LxGui Windows software.
-AMD
Airbus AMD234 Tests.
– AMD
This option can only be used with the provided LxGui Windows software.
-B787
Boeing 787B3-0147 Tests.
– B787
This option can only be used with the provided LxGui Windows software.
Misc. Options
-EXS
External Sync (see Notes)
-L22
Locking Knobs. Shaft lock screws replace knobs to prevent turning of
Voltage and Frequency shuttles.
-LAN
Ethernet LAN interface connection. RJ45 connector.
Note: When installed, RS232C interface is disabled.
-LKM
Clock and Lock Master. Enables synchronizing outputs of two Lx AC
sources, one acts as master.
This mode supports a frequency range of 45 to 819 Hz on standard
Lx/Ls models. See section 3.9.
-LKS
Clock and Lock Auxiliary. See -LKM for details. (see Notes) See section
3.9.
-LNS
Line Sync (see Notes)
-MB
Multi-box option. Provides additional controller(s) on 9000Lx/2,
12000Lx/2, 13500Lx/3 or 18000Lx/3 configurations allowing system to be
separated into individual functional units.
-RMS
Set of 2 Rack mount slides. (Left and Right) Recommended to mount Lx
Chassis in 19 inch instrument cabinet.
-RP
Replaces standard Lx numeric keypad keyboard/display with Ls type
dual shuttle knob style keyboard/display.
-RPV
Remote programming voltage. DC voltage input 0 to +10 VDC for 0 to
full-scale output voltage programming.