beautypg.com

AMETEK Lx Series II User Manual

Page 124

background image

User Manual

Lx / Ls Series II

120

7.5 Advanced Troubleshooting.

WARNING:

Do not connect 400-480V into the 208-240V unit, the result could be

a severely damaged unit.

CAUTION:

VOLTAGES UP TO 504 VAC AND 710 VDC ARE PRESENT IN

CERTAIN SECTIONS OF THIS POWER SOURCE.

WARNING:

THIS EQUIPMENT GENERATES POTENTIALLY LETHAL

VOLTAGES. DEATH ON CONTACT MAY RESULT IF PERSONNEL FAIL TO
OBSERVE SAFETY PRECAUTIONS. DO NOT TOUCH ELECTRONIC CIRCUITS
WHEN POWER IS APPLIED

Switch Off Units

Switch off each unit at the circuit breaker on the front panel as well as removing the input power
from the unit.

WARNING:

Wait 10 minutes for all internal capacitors to discharge.

Removing Cover

Remove the screws securing the top cover and remove it.

Initial Inspection

Make a visual inspection of the unit and ensure all the connectors are properly mated and there
are no loose wires.

7.6 Factory Assistance

If the problem with the cabinet or one of the power modules cannot be isolated, contact the
factory for assistance.

7.7 Fuses

See Table 7-2 for replaceable fuses and ratings for each of the sub assemblies in the Lx/Ls
Power source.