beautypg.com

AMETEK Lx Series II User Manual

Page 128

background image

User Manual

Lx / Ls Series II

124

8. Option -160: RTCA / DO-160D

8.1 General

This user manual assumes that the user is familiar with the text of the relevant DO160, section
16 test standard. No attempt is made to explain or elaborate on the actual test specification.

The RTCA/DO-160D option is capable of performing all sub-sections of RTCA/DO-160D, Section
16, RTCA/DO-160D change No2 and EUROCAE-14D / RTCA DO160D, Section 16 for the AC
Source signal. A selection is made available to specify the type of standard to be applied to the
EUT and the available EUT groups.

The voltage modulation tests for Airbus ABD0100.8 are supported by this option as well. The
voltage modulation levels for the Airbus version are specified differently from DO160. All other
tests are the same for Airbus and DO160.

Through out this document, RTCA/DO-160D change No2 will be referred to as RTCA2. Groups 1
through 3 will be used to refer to the EUROCAE-14D standard. Category A(CF), A(NF) and
A(WF) will be used to refer to the RTCA2 standard.

8.2 Initial Setup

Nominal parameters for the AC Power source are as follows:

Output Voltage

115V L-N or 230V L-N

Output Frequency

360 Hz to 800 Hz

Note: A setting outside these nominal values will disable the test and will prevent

access to the DO160 Menu screens. To execute all tests for the 230V L-N, the
power source must be capable of programming 360V RMS. This requires the -EHV
option output range pair (200/400V). If this option is not installed, some tests will
be skipped.

8.3 Tests Performed

8.3.1 NORMAL STATE

AC Source:

1. Normal State Voltage and Frequency test

2. Voltage unbalance test
3. Waveform Distortion test

4. Voltage Modulation test

5. Frequency Modulation test

6. Momentary Power Interrupt (Under voltage) test

7. Voltage Surge (Over voltage) test

8. Frequency Transients test(Group 1 only)

Frequency Variation test (Group 2 and 3 only)

This manual is related to the following products: