beautypg.com

AMETEK Lx Series II User Manual

Page 172

background image

User Manual

Lx / Ls Series II

168

11.7.2 TAC Group Tests

Three phase 400 Hz AC tests

TAC 102 Tests - Revisions A, B, C, D, E, F

TAC102

Steady State Voltage and Frequency - Rev A through F

Condition

Duration (s)

Balanced Voltage

Nominal Voltage

A

Vnom=115V, Fnom=400 Hz - Nominal

1800

B

Vnom=115V, Flow=393 Hz - Nominal

1800

C

Vnom=115V, Fhigh=407 Hz - Nominal

1800

Low Voltage

D

Vlow =108V, Fnom=400 Hz - Low

1800

E

Vlow=108V, Flow= 393 Hz- Low

1800

F

Vlow=108V, Fhigh=407 Hz - Low

1800

High Voltage

G

Vhigh=118V, Fnom=400 Hz - High

1800

H

Vhigh=118V, Flow=393 Hz- High

1800

I

Vhigh=118V, Fhigh=407 Hz - High

1800

Unbalanced Voltage

J

Va, Vb+3V, Vc+3V, Fnom

1800

K

Va, Vb-3V, Vc-3V, Fnom

1800

TAC 103 Tests - Revisions A, B, C, D, E, F

TAC103

Voltage Phase Difference - Rev A through F

Condition

Duration (s)

A

A = 0, B = 116, C = 240

1800

B

A = 0, B = 124, C = 240

1800

TAC 104 Tests - Revisions B, C, D, E, F

TAC104

Voltage Modulation - Rev B through F

Condition

Duration (s)

A

Vmod F = 1.0 Hz, V = 0.375 Vrms

1800

B

Vmod F = 1.7 Hz, V = 0.375 Vrms

1800

C

Vmod F = 10 Hz, V = 2.5 Vrms

1800

D

Vmod F = 25 Hz, V = 2.5 Vrms

1800

E

Vmod F = 70 Hz, V = 0.375 Vrms

1800

F

Vmod F = 100 Hz, V = 0.375 Vrms

1800

G

Vmod F = 200 Hz, V = 0.375 Vrms

1800

TAC 104 Tests

– Revision A

TAC104

Voltage Modulation - Rev A

Condition

Duration (s)

A

Vmod F = 1.0 Hz, V = 0.5 Vpp

1800

B

Vmod F = 1.7 Hz, V = 0.5 Vpp

1800

C

Vmod F = 10 Hz, V = 3.5 Vpp

1800

D

Vmod F = 25 Hz, V = 3.5 Vpp

1800

E

Vmod F = 70 Hz, V = 0.5 Vpp

1800

F

Vmod F = 100 Hz, V = 0.5 Vpp

1800

G

Vmod F = 200 Hz, V = 0.5 Vpp

1800

This manual is related to the following products: