beautypg.com

AMETEK Lx Series II User Manual

Page 160

background image

User Manual

Lx / Ls Series II

156

SAC102

Steady State Voltage and Frequency - Rev A

Condition

Duration (s)

High Voltage

G

Vhigh=118V, Fnom=400 Hz - High

1800

H

Vhigh=118V, Flow=380 Hz- High

1800

I

Vhigh=118V, Fhigh=420 Hz - High

1800

SAC 103 Tests

Voltage Phase Difference tests do not apply for single-

phase EUT‟s.

SAC 104 Tests - Revisions B, C, D, E, F

SAC104

Voltage Modulation Rev B - F

Condition

Duration (s)

A

Vmod F = 1.0 Hz, V = 0.375 Vrms

1800

B

Vmod F = 1.7 Hz, V = 0.375 Vrms

1800

C

Vmod F = 10 Hz, V = 2.5 Vrms

1800

D

Vmod F = 25 Hz, V = 2.5 Vrms

1800

E

Vmod F = 70 Hz, V = 0.375 Vrms

1800

F

Vmod F = 100 Hz, V = 0.375 Vrms

1800

G

Vmod F = 200 Hz, V = 0.375 Vrms

1800

SAC 104 Tests - Revisions A

SAC104

Voltage Modulation Rev A

Condition

Duration (s)

A

Vmod F = 1.0 Hz, V = 0.5 Vpp

1800

B

Vmod F = 1.7 Hz, V = 0.5 Vpp

1800

C

Vmod F = 10 Hz, V = 3.5 Vpp

1800

D

Vmod F = 25 Hz, V = 3.5 Vpp

1800

E

Vmod F = 70 Hz, V = 0.5 Vpp

1800

F

Vmod F = 100 Hz, V = 0.5 Vpp

1800

G

Vmod F = 200 Hz, V = 0.5 Vpp

1800

SAC 105 Tests

– Revisions E, F

SAC105

Frequency Modulation Rev E, F

Condition

Duration (s)

A

Fmod F = 1 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

B

Fmod F = 5 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

C

Fmod F = 10 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

D

Fmod F = 25 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800

E

Fmod F = 100 Hz/sec, Fmod Amp = 4 Hz± 2 Hz

1800