E
E
N
L3
L
L1
L2
F5 10 A
F4 10 A
Adept Quattro
s650/s800 Robot
1Ø 200–240 VAC
User-Supplied
AC Power Cable
Note: F4 and F5 are user-supplied, must be slow-blow.
3Ø
200–240 VAC
L = Line 1
N = Line 2
E = Earth Ground
200–240 VAC
Figure 4-5. Single-Phase Load across L1 and L2 of a Three-Phase Supply
Details for AC Mating Connector
The AC mating connector is supplied with each system. It is shipped in the Robot Accessory
Kit. The plug is internally labeled for the AC power connections (L, E, N).
Table 4-6. AC Mating Connector Details
AC Connector details
AC in-line power plug,
straight, female, screw
terminal, 10 A, 250 VAC
Qualtek P/N 709-00/00
Digi-Key P/N Q217-ND
NOTE: The AC power cable is not supplied with the system. However, it is
available in the optional Power Cable kit. See Table 4-1.
Procedure for Creating 200-240 VAC Cable
1. Locate the AC mating connector shown in Table 4-6.
2. Open the connector by unscrewing the screw on the shell and removing the cover.
3. Loosen the two screws on the cable clamp. See Figure 4-6.
4. Use 18 AWG wire to create the AC power cable.
Adept Quattro User's Guide, Rev F
Page 81 of 196