Adept s650HS Quattro User Manual
Page 167

Chapter 9: Maintenance - HS
l
Teach Restrict Verification
This verifies that the hardware Teach Restrict is functioning correctly.
The initial utility screen will tell you which functions are commissioned. If a function is not
commissioned, its verification wizard will not be displayed. Any displayed verification wizard
can be run at any time, to ensure that its function is working properly.
Prerequisites
l
The robot must be set up and functional.
l
The robot must use eAIB amplifiers.
The AIB amplifiers do not support these hardware functions, and these wizards will not
run.
l
Adept ACE software must be installed.
l
The Front Panel keyswitch must be in Auto mode.
Figure 9-5. Adept Front Panel
l
No E-Stops can be activated.
l
For Configuration (E-Stop and Teach Restrict), the eAIB Commissioning Jumper must be
plugged into the XBELTIO jack on the eAIB.
NOTE: This is the only time that this jumper will be used. It is part number
11901-000, and must be removed for Verification and normal operation.
Adept Quattro User's Guide, Rev F
Page 167 of 196