4 environmental and facility requirements, 5 mounting frame – Adept s650HS Quattro User Manual
Page 46

Chapter 3: Robot Installation - HS
CAUTION: The robot must always be shipped in an
upright orientation.
3.4 Environmental and Facility Requirements
The Quattro HS robot system installation must meet the operating environment requirements
shown in the following table.
Table 3-1. Robot System Operating Environment Requirements
Ambient temperature
1 to 40° C (34 to 104° F)
Humidity
5 to 90%, non-condensing
Altitude
up to 2000 m (6500 ft)
Pollution degree
2
Protection class: robot base
IP-66
Protection class: platform, arms
IP-67
NOTE: For robot dimensions, see Top Dimensions, s650 and s800 Robots on page 111.
NOTE: For power requirements, see Connecting 24 VDC Power to Robot on page 76 and
Connecting 200-240 VAC Power to Robot on page 79.
NOTE: The Adept SmartController must be installed inside a NEMA-1 rated enclosure. The
controller must not come into contact with liquids.
NOTE: For chemical cleaning information, refer to Chemical Compatibility on page 154.
3.5 Mounting Frame
The design of the robot mounting frame is the user’s responsibility.
l
The sample given for the s650H robot, while stiff enough for use with the Quattro HS
robots, was not designed for USDA applications.
l
The thickness of the frame mounting tabs is critical, as is the flatness of those tabs. See
Frame Mounting Tabs (following) and Mounting Surfaces on page 55.
l
The frame must be stiff enough to prevent excessive vibration.
l
You may want to design the frame so that the robot can be installed by lowering it from
the top.
The Quattro HS robot is designed to be mounted above the work area suspended on a user-
supplied frame. The frame must be adequately stiff to hold the robot rigidly in place while the
robot platform moves within the workspace.
While Adept does not offer robot frames for purchase, and the frame design is the
responsibility of the user, we provide some general guidelines as a service to our users.
Adept Quattro User's Guide, Rev F
Page 46 of 196