B.5.1. Avalon-MM Control Interface Signal
Table B–4
describes the Avalon-MM control interface signals for the ToD clock.
B.5.2. Avalon-ST Transmit Interface Signal
Table B–5
describes the Avalon-ST transmit interface signals for the ToD clock.
Table B–4. Avalon-MM Control Interface Signals for ToD Clock
Signal
Direction
Width
Description
csr_address[]
Input
2
Use this bus to specify the register address you
want to read from or write to.
csr_read
Input
1
Assert this signal to request a read.
csr_readdata[]
Output
32
Carries the data read from the specified register.
csr_write
Input
1
Assert this signal to request a write.
csr_writedata[]
Input
32
Carries the data to be written to the specified
register.
clk
Input
1
Register access reference clock.
rst_n
Input
1
Assert this signal to reset clk.
Table B–5. Avalon-ST Transmit Interface Signals for ToD Clock (Part 1 of 2)
Signal
Direction
Width
Description
time_of_day_96[]
Output
96
Timestamp from the ToD clock
■
Bits 0 to 15: 16-bit fractional nanosecond field
■
Bits 16 to 47: 32-bit nanosecond field
■
Bits 48 to 95: 48-bit second field
time_of_day_64[]
Output
64
Timestamp from the ToD clock
■
Bits 0 to 15: 16-bit fractional nanosecond field
■
Bits 16 to 63: 48-bit nanosecond field
time_of_day_96b_load_valid
Input
1
Indicates that the synchronized ToD is valid. Every
time you assert this signal, the synchronized ToD
is loaded into the ToD clock. Assert this signal for
only one clock cycle.
time_of_day_96b_load_data[]
Input
96
Loads 96-bit synchronized ToD from master ToD
clock to slave ToD clock within 1 clock cycle.
■
Bits 0 to 15: 16-bit fractional nanosecond field
■
Bits 16 to 63: 32-bit nanosecond field
■
Bits 64 to 95: 48-bit second field
time_of_day_64b_load_valid
Input
1
Indicates that the synchronized ToD is valid. Every
time you assert this signal, the synchronized ToD
is loaded into the ToD clock. Assert this signal for
only one clock cycle.
time_of_day_64b_load_data[]
Input
64
Loads 64-bit synchronized ToD from master ToD
clock to slave ToD clock within 1 clock cycle.
■
Bits 0 to 15: 16-bit fractional nanosecond field
■
Bits 16 to 63: 48-bit nanosecond field