beautypg.com

7 bus connection – Kipp&Zonen COMBILOG Data Logger User Manual

Page 25

background image

3.7

Bus Connection

In general the data logger is connected to the bus by applying
the signal leads A and B of the incoming bus cable and A' and
B' of the outgoing bus cable together to one terminal on the
module (figure 3.3).

Alternatively the bus can also be connected by a "stub cable"
as shown in figure 3.4.

Owing to the removable terminal, the bus connection to other
data loggers remains valid, even if one data logger is replaced
by another.

Figure 3.3 Connection of the data logger to the bus

Note: When connecting the logger to the bus, the two bus in-
terfaces A and B must not be interchanged.

Note: The stub cable should be as short as possible, not
longer than 30 cm (12 inch).

Hardware Manual COMBILOG 1022

25

A
B