pointer setting. If there is no further communication within 1
minute, password release is deleted.
For passwords, only capital letters and numbers are accepted.
char
meaning
length
range
#
start delimiter for request telegram with
check sum
1
ASCII "#"
>
start delimiter for response telegram
with check sum
1
ASCII ">"
$
start delimiter for request telegram
without check sum
1
ASCII "$"
=
start delimiter for response telegram
without check sum
1
ASCII "="
end delimiter (carriage return)
1
hex 0D
ACK
positive acknowledge
1
hex 06
NAK
negative acknowledge
1
hex 15
aa
destination address
2
ASCII
"01".."7F"
cc
check sum
2
ASCII
"00".."FF"
kk
channel number
- for internal channels
- for external channels
2
ASCII
"01".."20"
"80".."BB"
v..v
device identification
28
ASCII - string
s..s
device information
28
ASCII - string
z..z
status information
12
ASCII - string
i..i
channel information
32
ASCII - string
d..d
channel value
max. 8 ASCII - string
b..b
events
variable ASCII - string
e
error code
1
ASCII "1".."2"
t..t
date and time
12
ASCII - string
n..n
measuring rate and averaging interval
7
ASCII - string
a..a
number of events
5
ASCII - string
p..p
password
max. 8 ASCII - string
Table 11.10 Explanation of the command characters in the ASCII-pro-
tocol
Hardware Manual COMBILOG 1022