11.11 Modem Connection

In case of using a telephone or GSM modem with the
COMBILOG the modem must at first be initialized by means of
a terminal program. Set the interface settings of the terminal
program to 19200 bps, no parity, and enter the following AT
commands. Refer to your modem manual for a detailed de-
scription of the commands, because some commands may dif-
fer depending on the modem type.

Load default settings

AT&F

Set baud rate to 19200 bps

device dependent

Set auto answer on

*

ATS0=1

Set DSR on

AT&C0

Ignore DTR

AT&D0

Save configuration

AT&W0

* In case the modem is connected to the RS232 port of the
COMBILOG, the data logger will response the incoming call
after 4 rings automatically. Note, that the ring will not be recog-
nised at the RS485 port.

Set the RS232 interface of the COMBILOG to 19200 bps, no par-
ity.

Prepare a cable between modem and COMBILOG as shown:

COMBILOG 1022

MODEM

25-pin

9-pin

TX

2

3

RxD

RX

3

2

TxD

GND

7

5

GND

4

7

RTS

5

8

CTS

6

6

DSR

20

4

DTR

Hardware Manual COMBILOG 1022